5.4 inch OTDR Tester M-OTDR-404 with wavelength 1310 / 1550nm, dynamic range 28/26dB
Specification:
Specification |
||
Model Number |
M-OTDR-404 |
|
Size & Display |
5.4 inch
touch screen with retina display, 1920*1152 resolution |
|
Network Port |
Dual 1000M
LAN port, 10/100/1000M auto adapt |
|
WIFI |
Built in
2.4G WIFI, speeds150M, display wireless camera image |
|
H.265 mainstream test |
H.265
& H .264 IP, 8K video display via mainstream |
|
IP camera test |
Support
500 brands IP camera test |
|
IP discovery |
Auto-scan the whole network segment IP address |
|
HD coaxial camera test |
8MP HD-TVI,
8MP HD-CVI , 8MP AHD camera test, UTC control & call OSD menu |
|
CVBS camera test |
1 channel
BNC input & 1 channel BNC looped output, NTSC/PAL (Auto adapt) |
|
Zoom Image |
4x zoom,
enlarge image, screen snapshot, save, view and record and playback |
|
RJ45 cable TDR test |
Test cable pair status, length,
attenuation, reflectivity, and impedance, skew etc.
measurement range 180M. |
|
HDMI input / output |
4K 60FPS
HDMI input, 4K 30 FPS HDMI output |
|
VGA input |
Support
1280x1024/960/800/768/720P 60FPS, 1152x870P 60FPS, 1024x768P 60FPS, 800x600P
60FPS, 640x480P 60FPS resolution |
|
Power output |
48V PoE /
24V2A / 12V 3A / 5V 2A power output |
|
UTP cable test |
Test UTP
cable connection status and display on the screen. Read the number on the
screen. detect the near-end, mid-end and far-end fault point of RJ45 cable
connector, also can test shield cable |
|
Data monitor |
Captures
and analyzes the command data from controlling device, also can send
hexadecimal |
|
Network test |
Trace route, Link monitor, DHCP
server, port flashing, Ping test |
|
Cable tracer |
Search BNC cable, network cable and telephone cable from the mess
cables. Cable tracer and UTP cable test app in the same interface, also
can search shield cable |
|
Electroscope |
Voltage
range |
AC12-1000V |
Frequency |
50/60Hz |
|
Alarm type |
Sounds and
light double alarms |
|
Level |
CAT.III 1000V
/ CAT.IV 600V;CE |
|
PoE Voltage test |
Measurement
POE switch or PSE power supply voltage and cable connection status |
|
Visual fault locator |
10mW
visual fault locator with 650nm wavelength, emit red laser sources to test
multi-mode and single mode fiber’s bending and breakage, test range 8KM |
|
Optical power meter |
Wavelength: 1625,1550nm,1490nm,1310nm,1300nm,850nm,
measurement range: -70 ~ +10 dBm, for optical power testing and Fiber
link loss relative measurement |
|
Power |
||
External power supply |
DC 12V(2A) |
|
Battery |
Built-in
7.4V Lithium polymer battery, 5200mAh |
|
Rechargeable |
After
charging 2.5 hours, normal working time 11 hours |
|
Parameter |
||
Operation setting |
OSD menu,
select your desired language: English, Portuguese, Korean, Russian, Italian,
French, Polish, Spanish, Japanese, Turkish, Deutsch, Serbian, Czech,
Vietnamese etc |
|
Auto off |
5-30 (mins) |
|
Working environment |
||
Working Temperature |
-10℃ --- +50℃ |
|
Dimension |
220mm x 150mm x 46mm (Tester); 320mm x 290mm x 98mm (box) |
|
Weight |
846g (Tester); 2050g (Tester with spare parts, black package, box) |
|
OTDR technical data |
||
Wavelength
(nm) |
1310 / 1550nm |
|
Dynamic
ange(dB)2 |
28 / 26dB |
|
Pulse
width (ns) |
5,10,20,30,50,80,160,300,500,800,1000,2000,4000,6000,10000,20000 |
|
Testing
distance |
≤105 Km |
|
Event blind
zone (m)3 |
≤2.2m |
|
Attenuation
blind zone (m)3 |
≤15m |
|
Linearity
(dB/dB) |
±0.05 dB/
dB |
|
Loss
threshold (dB) |
0.05 |
|
Loss
resolution ratio (dB) |
0.01 |
|
Sampling
resolution ratio (m) |
0.125~8 |
|
Sampling
point |
32K |
|
Distance
uncertainty (m) |
±(1 m +
5×10-5× distance +
sampling interval) |
|
Distance
scope (km) |
0.5,1,2,5,10,25,50,100,200 |
|
Typical
real-time refreshing duration |
1s |
|
Measurement
duration |
5sec,
10sec, 15sec, 30sec, 1min, 2min, and 3min are selectable |
|
Interface
type |
FC-PC |
|
Remarks: 1. The technical specification describes the ensured performance
of the instrument when using typical PC model connector to measure, without
considering the uncertainty caused by optical fiber refractivity. 2. Dynamic range is the data measured under the condition of the
maximum pulse width and 3 minutes of average time. Dynamic range is the data
measured under the condition of 200km/20000ns/3min. 3. Measuring conditions of
blind zone: reflection event is within 5Km, reflection strength is 45dB.
Measured by the minimum pulse width. |